Search results for "HDR brachytherapy"

showing 3 items of 3 documents

Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy.

2014

In surface and interstitial high-dose-rate brachytherapy with either (60)Co, (192)Ir, or (169)Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields…

HDR brachytherapyMaterials sciencesuperficial and interstitialmedicine.medical_treatmentBrachytherapyBrachytherapydosimetric perturbationModels BiologicalSensitivity and SpecificityImaging phantomLead shieldingOpticsRadiation ProtectionShieldBody surfacemedicineHumansScattering RadiationComputer SimulationRadiometryWaste Management and DisposalMonte Carlo simulationbusiness.industrytransmissionPublic Health Environmental and Occupational HealthAbsorption RadiationReproducibility of ResultsRadiotherapy DosageGeneral MedicineEquipment DesignHigh-Dose Rate BrachytherapyEquipment Failure AnalysisLeadElectromagnetic shieldinglead shieldbusinessNuclear medicineBolus (radiation therapy)Journal of radiological protection : official journal of the Society for Radiological Protection
researchProduct

Risk assessment of component failure modes and human errors using a new FMECA approach: application in the safety analysis of HDR brachytherapy

2014

Failure mode, effects and criticality analysis (FMECA) is a safety technique extensively used in many different industrial fields to identify and prevent potential failures. In the application of traditional FMECA, the risk priority number (RPN) is determined to rank the failure modes; however, the method has been criticised for having several weaknesses. Moreover, it is unable to adequately deal with human errors or negligence. In this paper, a new versatile fuzzy rule-based assessment model is proposed to evaluate the RPN index to rank both component failure and human error. The proposed methodology is applied to potential radiological over-exposure of patients during high-dose-rate brach…

HDR brachytherapySafety ManagementComputer sciencemedicine.medical_treatmentBrachytherapyHuman errorBrachytherapyRisk AssessmentRadiation ProtectionComponent (UML)medicineHumansComputer SimulationRadiation InjuriesWaste Management and Disposalhuman errorSettore ING-IND/19 - Impianti Nuclearirisk priority numberModels StatisticalFuzzy ruleMedical ErrorsIncidenceRank (computer programming)Public Health Environmental and Occupational HealthGeneral MedicineReliability engineeringEquipment Failure AnalysisSurvival RateFailure mode effects and criticality analysisEquipment FailurePatient Safetyfuzzy logicRadioactive Hazard ReleaseRisk assessmentFailure mode and effects analysisFMECA
researchProduct

A generic TG-186 shielded applicator for commissioning model-based dose calculation algorithms for high-dose-rate Ir-192 brachytherapy

2017

PurposeA joint working group was created by the American Association of Physicists in Medicine (AAPM), the European Society for Radiotherapy and Oncology (ESTRO), and the Australasian Brachytherapy Group (ABG) with the charge, among others, to develop a set of well-defined test case plans and perform calculations and comparisons with model-based dose calculation algorithms (MBDCAs). Its main goal is to facilitate a smooth transition from the AAPM Task Group No. 43 (TG-43) dose calculation formalism, widely being used in clinical practice for brachytherapy, to the one proposed by Task Group No. 186 (TG-186) for MBDCAs. To do so, in this work a hypothetical, generic high-dose rate (HDR) Ir-19…

HDR brachytherapymedicine.medical_specialtyComputer sciencemedicine.medical_treatmentBrachytherapyEQUATION SOLVERIr-192computer.software_genreGEC-ESTROImaging phantom030218 nuclear medicine & medical imaginglaw.invention03 medical and health sciences0302 clinical medicineMONTE-CARLOlawVoxelGEOMETRIESShielded cableAAPMmedicineMedical physicsRadiation treatment planningGEANT4business.industryMonte Carlo methodsGeneral MedicineDOSIMETRIC ACCURACYTRANSPORTmodel based dose calculation3. Good healthRadiation therapyTG-186030220 oncology & carcinogenesisAbsorbed doseSIMULATIONshielded applicatorTG-43 FORMALISMNuclear medicinebusinessDose rateAlgorithmcomputer
researchProduct